Non-inferiority (NI) trials are increasingly used in clinical research, particularly when placebo control is unethical. Despite their widespread adoption, NI trials are frequently misdesigned and misinterpreted, often due to poorly justified margins, inappropriate control selection and misunderstanding of statistical conclusions. This combination of issues may lead to misleading evidence with consequences for clinicians, regulators and the wider public.
A non-inferiority trial aims to demonstrate that a new treatment is not unacceptably worse than an active control by more than a pre-specified margin (Δ). NI is concluded if the estimated treatment effect and its confidence interval lie entirely within this margin.
The NI margin must be justified on both clinical and statistical grounds, preserving a clinically meaningful proportion of the control treatment’s established effect.
We will use a simulated 2008 clinical and regulatory setting to examine the statistical design of a pivotal NI trial for the BioMimics 3D vascular stent. The case study is based on the original development of the device, led by Kevin Heraty, lead scientist on BioMimics 3D.
The BioMimics 3D stent is a peripheral vascular stent implanted in the leg or arm to improve blood flow in patients with peripheral vascular disease (narrowing of the the peripheral blood vessels). Unlike conventional straight stents, it features a three-dimensional helical design, intended to improve vascular performance and blood flow patterns in the affected areas.
To reflect a real-world trial planning scenario, we meet with Kevin Heraty to discuss key statistical decisions, including endpoint selection, performance goals, and sample size requirements. This ensures the statistical design is informed by clinical and device-specific considerations.
The BioMimics 3D stent is treated as the investigational device in a hypothetical NI trial, with established peripheral stents used as the active control. Evidence available from up till 2008 is used to guide the design, and simulated trial data will be used to assess non-inferiority conclusions and highlight common sources of misinterpretation.
TEXT TEXT TEXT
Margin-Jinn is an interactive Shiny application we developed as a part of this project in order to support statistical planning for NI trials. The app supports visual exploration of sample size requirements across different assumptions, highlighting the sensitivity of NI designs to choices that are often fixed or under-examined during trial planning.
In this study, Margin-Jinn is applied to the BioMimics 3D case study to justify and critically assess sample size decisions under realistic design scenarios.